Remove the PCI riser assembly.
Move the shorting block on the Boot Block jumper (J1B1) back to pins
Replace the PCI riser assembly.
Follow the instructions in “Closing the server case” on page 44.
The FRU/SDR must be updated whenever you add additional hardware to your server that must be monitored by the BMC. This includes adding a redundant power supply module, adding redundant
Each time you update the FRU/SDR, we recommend that you check support.gateway.com for the most current version of the utility. If a newer version is available than the one included on the SCCD, download the newer version and use it instead of the SCCD in the following procedure.
To update the FRU/SDR:
1
2 Put the System Companion CD in the CD drive and change directories (to the CD drive) to access it.
3
4 Select one of the following options (if in doubt, choose the second option and update both):
Update just the SDR repository - Select this option when sensor information needs to be changed (for example, if the CPU is upgraded to a higher speed or if memory is replaced).
Update the FRUs and the SDR repository (and mBMC TBLs - if the IMM module is not present) - Select this option if have installed additional hardware (for example, a redundant power supply or system fans, or additional memory).
5 When you are asked if you have an optional cooling kit installed, type Y if your system has redundant fans installed or N if you system has only the basic fans installed.
6 Exit the utility, remove the System Companion CD, and reboot your server.