1.Installa manualgas lineshut-offvalvein the gas linein an easilyaccessedlocationoutsideof the range.Makesure everyoneoperatingthe rangeknowswhereandhowto shutoff the gas supplyto the range.

2.Installmale 1/2”flareunionadapterto the 1/2”N~ internalthread elbowat inletof regulator.On models eqtippedAh dud ~wners, installthe malepipethread end of the 1/2”flareunionadapterto the 1/2”N~ internalthread at klqt ofpressure regulator. Usea backupwrenchonthe regulatorfitting to avo~ddamage.

Wheninstallingthe rangeborn the front, removethe 90° elbowforeasierinstallation.

Electid Reqdremenk

120-volt,60Hertz,properlygroundedbranch circuitprotectedby a I$amp or 20-ampcircuit breakeror timedelayfuse.

ExtensionCord Cautions

Because of potential safety hazards associated with certain conditions, we strongly recommend against the use of an extension cord. However, ifyou sti~ elect to use an extension cord, it is absolutely necessary that it be a UL-listed,

3-wiregrounding-type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to, or greater than, the branch circuit rating.

D

3.Installmale 1/2” or 3/4”flareunionadapter to the N~ internalthread ofthe manualshut- offvalve,takingcare to back-upthe shut-off valveto keep it fromturning.

~.Connectflexiblemetalapplianceconnector to the adapteron the range.Positionrange to permitconnectionat the shut-offvalve.

~.men allconnectionshavebeen made,make sure allrange controlsare in the offpositionand turn on tie maingas supplyvalve.Usea liquid leakdetectorat alljointsand connectionsto checkfor leaksin the system.

CAmON: DO N~ USEA ME TO

CHECKFORGAS~.

Whenusingtest pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individud shut-off valvefrom the gas supply piping. When using test pressures of 1/2 psig or less to test the

gas SUpply system, simply isolate the range from

the gas supplysystemby closingthe individual shut-offvalve.

Gmuntin$

MORTM—(Please read wetifly)

FOR PERSONALSAPETY,THIS APPLIANCE MUSI’BE PROPEWY GROUNDED.

The powercord ofthis applianceis equipped witha three-prong(grounding)plugwhich mateswitha standardthree-pronggrounding

 

.

wallreceptacle

PREFERRED

f

to mintize the

METHOD

-\

possibilityof

 

 

QQ 9

electricshock

0

%

hazardhorn

 

~,

this appliance.

VB

The customer

 

ENSUREPROPER

shouldhavethe

 

II

GROUNDEXISTS

wallreceptacle

BEFOREUSE

andcircuit

..-.checked by a

qua~ed electrician to make sure the receptacle is properly grounded.

Wherea standardtwo-prongwallreceptacleis encountered,it is the personalresponsibilityand obligationoftie customerto haveit replacedwith a properlygroundedthree-prongwallreceptacle.

B

*34

Page 35
Image 35
GE 49-8338 installation instructions MsTALLATIoNmSTRucTIoNs, Gmuntin$