Henny Penny OFG-391 manual Filling or Adding Shortening

Models: OFG-391

1 70
Download 70 pages 43.6 Kb
Page 28
Image 28

Model OFG- 391

3-5. FILLING OR ADDING SHORTENING

The shortening level must always be above the heating elements when the fryer is heating and at the frypot level indicators on the rear of the frypot (Figure 3-3). Failure to follow these instructions could result in a fire and/or damage to the fryer.

When using solid shortening, it is recommended to melt the shortening on an outside heating source before plac- ing it in the frypots. The burner tubes must be completely submerged in shortening. Fire or damage to the frypot could result.

1.It is recommended that a high quality frying shortening

be used in the open fryer. Some low grade shortenings have a high moisture content and will cause foaming and boiling over.

To avoid severe burns when pouring hot shortening into frypot, wear gloves and take care to avoid splashing.

2.The gas model requires 130 lbs. (59 Kg.) The frypot has 4 level indicator lines inscribed on the rear wall of the frypot which show when the heated shortening is at the proper level. Figure 3-3.

3.Cold shortening should be filled to the lower indicators.

Figure 3-3

BE CERTAIN THE SHORTENING IS NEVER

ABOVE THE UPPER LEVEL INDICATOR LINES.

FAILURE TO FOLLOW THESE INSTRUCTIONS

CAN RESULT IN SHORTENING OVERFLOWING

THE FRYPOT CAUSING SERIOUS BURNS, PER-

SONAL INJURY, FIRE AND/OR PROPERTY

DAMAGE.

3-8

703

Page 28
Image 28
Henny Penny OFG-391 manual Filling or Adding Shortening