3-19. INFORMATION MODE

Press

and “6. PMP_ AIR_” shows in display.

(Continued)

 

 

 

 

Press

to view the amp “DRAW” status of the pump motor

 

output and air valve output. “PMP ” and “AIR ” in the

 

display means the amps are good. Aflashing “X” behind the

 

“PMP” or “AIR” means too much current.

 

Press

to view the No Connect/Ground (“NC/GND”)

 

status of each output. This monitors a possible problem with

 

the relays on the output PC board.

 

Press

to continue onto the OIL TMP reading.

 

7. OIL TMP

 

 

This step shows the present peanut oil temperature. The

 

display shows “7. OIL TMP (temp.)”.

 

Press

to continue onto the CPU TMP reading.

 

8. CPU TMP

 

 

This step shows the present PC board temperature.

 

Press

to continue onto the ANALOG reading.

 

9. ANALOG <1> 2.86V

 

 

This step displays the present status of any channel of the

 

controller’s a to d converter. This feature may be useful to a

 

technician troubleshooting a problem with the fryer or

 

controller.

 

 

The displayed value can be toggled between volts and bits

 

by pressing . If the displayed value has a decimal point,

 

it is voltage (0 to 5 VDC). If no decimal point is shown, the

 

value is a-to-d bits (0 - 4095).

 

 

Press and hold

to exit Information Mode at any

 

 

time, or after 2 minutes, controls automatically exit

 

 

back to normal operation.