3-17. SPECIAL PROGRAM

The Special Program mode is used to set more detailed

MODE

parameters listed below.

 

SP-1

· Degrees Fahrenheit or Celsius

 

SP-2

· Language: English, French, German,

 

SP-3

 

Spanish, and Portuguese

 

·

Systeminitialization

 

SP-4

·

Audio volume

 

SP-5

·

Audio tone

 

SP-6

· Type of shortening to be melted - liquid, solid

 

SP-7

·

Idle Mode

 

SP-8

·

FilterTracking

 

SP-9

·

Product buttons

 

SP-10

·

Clean-out minutes

 

SP-11

·

Clean-out temperature

 

SP-12

·

Nominal amps reading

 

SP-13

· Amps reading low limit (percentage)

 

SP-14

· Amps reading high limit (percentage)

 

SP-15

· Program code change

 

SP-16

· Usage code change

 

SP-17

· Change shortening - A-Cook Cycles

 

SP-18

· Change shortening - B-Hours

1.Press and hold for 5 seconds until

“L-2” and “LEVEL 2”, followed by, “SP PROG” and “ENTER CODE shows in the display.

2.Enter code 1, 2, 3, and “SP- 1 “, “TEMP, UNITS” shows in the display.

If a bad code is entered, an alarm sounds and “BAD CODE” shows on the display. Wait a few seconds, the control reverts back to the Cook Cycle, and repeat the above steps.

To exit from the Special Program Mode at any time, press

and hold button for 2 seconds, or to roll back to

previous setting, press

.

Degrees Fahrenheit or Celsius (SP-1) a. Follow steps 1 and 2 above.

 

b. The display flashes “SP- 1” and “TEMP, UNITS”, along

 

with “ºF” or “ºC”. Press

 

buttons to toggle from “ºF” to “ºC”, or vice versa.