Verify that the flat flexible cable connection from the formatter to the memory-card reader assembly is firmly connected.

If the card is not defective and the card is in the correct slot, the circuit board might have been inadvertently damaged by an electrostatic discharge from someone inserting a memory card. If this is the case, replace the memory-card reader assembly. If the error still occurs, replace the formatter.

Component tests

The control-panel tests require touching the Left Arrow button and the Cancel button on the touchscreen when they are not illuminated. Use the figure below to locate these buttons on the touchscreen.

Figure 2-1Control-panel test

Control-panel tests

Test the control-panel display

1.Touch the Setup button.

2.Touch the Left Arrow button and the Cancel button at the same time.

3.Touch the Setup button.

4.Open the 2ndry Service menu.

5.Touch the Dispaly Test item.

Test the control-panel buttons

1.Touch the Setup button.

2.Touch the Left Arrow button and the Cancel button at the same time.

3.Touch the Setup button.

ENWW

Troubleshooting tools 117

Page 143
Image 143