HP CLJ M375NW PRO 300 CE903A#BGJ, M475 CE863A Reinstall the control panel and right-arm mount

Models: M475 CE863A CLJ M375NW PRO 300 CE903A#BGJ

1 346
Download 346 pages 9.9 Kb
Page 75
Image 75

4.Slide the control panel right-arm mount to the right to remove it from the scanner chassis. Figure 1-62Remove the control panel and right-arm mount (3 of 3)

Reinstall the control panel and right-arm mount

1.Slide the control panel right-arm mount assembly into the mounting points on the scanner chassis.

2.Install three screws (callout 1) and attach the grounding wire (callout 2).

IMPORTANT: The grounding wire and the two FFCs must move freely. If the grounding wire is tangled with the FFCs, or is retracted too far into the control panel swivel, it might be too short to reach the mounting point on the chassis.

Figure 1-63Reinstall the control panel and right-arm mount (1 of 2)

1

2