Table | |
|
|
Event code | Description |
|
|
59.3000 | Fuser motor startup error |
|
|
59.4000 | Fuser motor error |
|
|
59.5000 | Image drum motor startup |
|
|
59.5300 | Image drum motor startup |
|
|
59.6000 | Image drum motor rotation |
|
|
59.6300 | Image drum motor rotation |
|
|
59.7000 | Black developer motor startup error |
|
|
59.7300 | Yellow developer motor startup error |
|
|
59.8000 | Black developer motor rotation error |
|
|
59.8300 | Yellow developer motor rotation error |
|
|
59.9000 | ITB motor start error |
|
|
Table |
| |
|
|
|
Event code | Description | Solution |
|
|
|
20.0000 | Memory out | 1. Turn off the power by using the power switch, and then wait at least 30 |
|
| seconds. |
|
| 2. Turn on the power and wait for the product to initialize. |
|
| If the error persists, break the job into smaller jobs that contain fewer pages. |
|
| If the error persists, update the firmware. |
|
| NOTE: For |
|
| help solve this problem. |
|
|
|
54.0100 | Environmental sensor error | Verify that the DC controller connectors are firmly connected. |
|
| If the error persists, replace the temperature/humidity sensor. |
|
| If the error persists, replace the DC controller. |
|
|
|
178 Chapter 2 Solve problems | ENWW |