2.Lower the Tray 1 paper pickup assembly by pushing down on the edges of the assembly. Figure 1-12Remove the Tray 1 pickup roller (1 of 3)

3.Carefully raise the front of the product.

WARNING! Do not place the product face-up resting on the rear cover and rear door. Excess toner might enter the laser/scanner assembly and contaminate the mirrors, causing print-quality problems. The laser/scanner is not a FRU. If the laser/scanner mirrors are contaminated, the entire product must be replaced.

CAUTION: The document feeder and scanner cover are not captive and can open suddenly when the product is placed front-side face up. Always support the document feeder and scanner cover before placing the product front-side face up.

CAUTION: Do not lift the product grasping the front door and Tray 2 cavity.

Figure 1-13Remove the Tray 1 pickup roller (2 of 3)

18 Chapter 1 Removal and replacement

ENWW