Document feeder pickup roller assembly

IMPORTANT: The document feeder pickup roller must be shipped in the down position.

1.Open the document feeder cover.

2.Disconnect one spring (callout 1).

Figure 1-10Remove the document feeder pickup roller assembly (1 of 2)

1

3.Lift up on the end of the assembly, and then slide it toward the control panel to remove it. Figure 1-11Remove the document feeder pickup roller assembly (2 of 2)

2

1

16 Chapter 1 Removal and replacement