Diagnostic Utilities

x25stat

x25stat

This command displays the status, configuration, and VC statistics of an X.25 interface. See the man pages on x25stat for syntax and parameter information.

Example 1: Displaying the Current Configuration
x25stat -c-d x25_0

 

 

 

 

 

-------- X.25 CONFIG -----------

 

 

 

General Parameters:

 

 

 

 

 

X.121 Address: 110

 

 

 

 

X.121 Pkt Addr:

 

110

 

 

 

 

Programatic Access Name: x25interface_0

 

 

Level 1 parameters

 

 

 

 

 

 

Linespeed: external clock

 

 

 

Level 2 parameters

 

 

 

 

 

 

t1 [frame timeout]:

3000 ms

 

 

 

t3 [idle timer]:

 

12000 ms

 

 

 

n2 [retransmissions]: 3

 

 

 

Max. Framesize:

 

 

269

 

 

 

Level 2

Window:

 

 

7

 

 

 

Level 3 parameters

 

 

 

 

 

 

network

type:

DTE_8

 

 

 

 

VC parameters ( Low High ) values :

 

 

 

PVCs

:

0

0

 

 

 

 

SVCs In

:

0

0

 

 

 

 

SVCs 2ways:

1

64

SVCs Out

:

0

0

Total Number of

 

VCs configured: 64

 

 

 

Default

inbound

 

packet size:

128

 

 

Default

outbound packet size:

128

 

 

Default

inbound

 

window size:

2

 

 

Default

outbound window size:

2

 

 

Default

inbound

 

throughput class: 12

 

 

Default

outbound throughput class:12

 

 

Facilities

settings:

 

 

 

 

Fast Select is : DISABLED

 

 

 

Flowcontrol Neg

 

is : OFF

 

 

 

Reverse

Charging is : DISABLED

 

 

 

118

Chapter 5