Configuration

Configuring the High Availability Feature

#e.g.# SERVICE_NAME [1] = <other name>

#SERVICE_CMD [1] = <other monitor>

#START OF CUSTOMER DEFINED FUNCTIONS function customer_defined_run_cmds

{

#ADD customer defined run commands

: # do nothing instruction, because a function must contain at least one command. x25init -c /etc/x25/x25config_1 -a /etc/x25/ip_to_x121_map

sleep 5

test_return 51

}

function customer_defined_halt_cmds

{

#ADD customer defined halt commands

: # do nothing instruction, because a function must contain some command. #stopping the specific X.25 card means the signal modem will be down x25stop -d /dev/x25_1

test_return 52

}

Checking the Configuration

Check that your configuration is correct using x25server, x25check, and ping.

x25server Run the x25server command. This starts a background process that waits for packets from an x25check command and sends a reply.

x25check Execute the x25check command, using your X.121 address:

$ x25check 250207

X25CHECK (c) COPYRIGHT Hewlett-Packard Company 1988.

Test Starts on .. Wed Dec 8 09:15:01 1993

Initialization of the test...

CALL packet sent ...

The following figures have been measured on the network:

Set up time : 267 ms

Remote Connection Succeeded

Execute the x25check command again, but this time with data packets:

Chapter 3

79