Configuration

Configuring the X.25 Link

Figure 3-5

Verify Level 3 Values

Step

2. Enter or modify field values as required (refer to the field descriptions

 

 

below).

 

Table 3-6

 

Verify Level 3 Values Field Descriptions

 

 

 

 

 

 

Fast Select

If fast select is enabled (Yes), up to 128 octets of

 

 

Accepted

information can be transferred in call request and

 

 

 

clear packets. The default is No (disabled). See

 

 

 

your subscription form.

 

 

 

 

 

 

Flow Control

The default is No (disabled). Use the value given

 

 

Negotiation

on your subscription form.

 

 

 

 

 

 

Reverse Charge

If reverse charge is enabled (Yes), reverse charge

 

 

Accepted

calls can be accepted by the application. If reverse

 

 

 

charge is disabled (No), X.25 rejects reverse

 

 

 

charge calls automatically. The default is No. Use

 

 

 

the value given on your subscription form.

 

 

 

 

 

 

Throughput Class

Throughput class refers to line speed. If it is

 

 

Negotiation

enabled (Yes), the Switched VC Negotiated value

 

 

 

is used; if disabled (No), no throughput class

 

 

 

negotiation is accepted. The default is No.

 

 

 

 

40