X.25 Configuration Files and Examples

Example Files

Table B-6

(Continued)

#Level 3 Parameters

#Mandatory Parameters - virtual circuit parameters

#logical channel id, start num [1-4095], type, how many

#At least one lci type (PVC, incoming, two-way or outgoing SVC)

#needs to be configured.

#lci 1 pvc 5

# 5 permanent VCs starting at LCI 1

#lci 255 insvc 5

# 5

one-way incoming SVCs starting at LCI

#lci 2048

svc 6

255

 

#lci 3072

outsvc 6

# 6

two-way switched SVCs starting at LCI

 

 

2048

 

 

# 6

one-way outgoing SVCs starting at LCI

 

 

3072

networktype DTE_84 fast_select disabled reverse_charge disabled

#CCITT 1984, DTE (see /etc/x25/x25_networks)

#disallow incoming calls with call user data

#disallow incoming calls requesting reverse changes

def_inpacketsize 128

# default packetsize

def_outpacketsize 128

# default packetsize

def_inwindow 2

# default window size

def_outwindow 2

# default window size

# def_inthruputclass

# default thruput class

19200

# default thruput class

# def_outthruputclass

 

19200

 

flowcontrol off

neg_inpacketsize 128 neg_outpacketsize 128 neg_inwindow 2 neg_outwindow 2

#flow control negotiation not allowed

#offered pkt size if using flow control negotiation

#offered pkt size if using flow control negotiation

#offered wndw size if using flow control negotiation

#offered wndw size if using flow control negotiation

thruputclass off

Appendix B

229