Table 9-1Numeric Codes and Text Messages (continued)

Control panel message

Description

Recommended action

 

 

 

 

2201-MEBx Module did not checksum

Memory error during POST execution of the

1.

Reboot the computer.

correctly

Management Engine (ME) BIOS Extensions

2.

Unplug the power cord, re-seat the

 

option ROM.

 

 

 

memory modules, and reboot the

 

 

 

computer.

 

 

3.

If the memory configuration was

 

 

 

recently changed, unplug the power

 

 

 

cord, restore the original memory

 

 

 

configuration, and reboot the

 

 

 

computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

2202-PMM Deallocation Error during MEBx

Memory error during POST execution of the

1.

Reboot the computer.

cleanup

Management Engine (ME) BIOS Extensions

2.

Unplug the power cord, re-seat the

 

option ROM.

 

 

 

memory modules, and reboot the

 

 

 

computer.

 

 

3.

If the memory configuration was

 

 

 

recently changed, unplug the power

 

 

 

cord, restore the original memory

 

 

 

configuration, and reboot the

 

 

 

computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

2203-Setup error during MEBx execution

MEBx selection or exit resulted in a setup

1.

Reboot the computer.

 

failure.

2.

Unplug the power cord, re-seat the

 

 

 

 

 

memory modules, and reboot the

 

 

 

computer.

 

 

3.

If the memory configuration was

 

 

 

recently changed, unplug the power

 

 

 

cord, restore the original memory

 

 

 

configuration, and reboot the

 

 

 

computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

2204-Inventory error during MEBx execution

BIOS information passed to the MEBx

1.

Reboot the computer.

 

resulted in a failure.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

 

2205-Interface error during MEBx execution

MEBx operation experienced a hardware

1.

Reboot the computer.

 

error during communication with ME.

2.

If the error persists, update to the latest

 

 

 

 

 

BIOS version.

 

 

3.

If the error still persists, replace the

 

 

 

system board.

 

 

 

 

POST Numeric Codes and Text Messages 179

Page 187
Image 187
HP E3S33UT#ABA, E3S36UT#ABA, Pro 6305 C1E21UT#ABA manual Post Numeric Codes and Text Messages