3.12 Removing the System Reporter Components

This section describes how to remove the 3PAR System Reporter Components. This includes removing the System Reporter sampler and default database, as well as deleting the optional MySQL database (when applicable).

3.12.1 Removing the System Reporter Tools on Windows

To remove the System Reporter tools on WIndows:

1Go to the Windows Control Panel, open Administrative Tools and then Services.

2In the Services window, right-click 3PAR System Reporter sampler and then click Stop. Close the Services window.

3From a command prompt, change to the directory where you installed the 3PAR System Reporter tools:

#cd \program files\3par\system reporter

4Execute the following command:

#winserv uninstall "3PAR System Reporter sampler”

5Exit and close the command prompt window.

#exit

6Using Windows Explorer, go to the location where you installed the 3PAR System Reporter tools (for example, C:\Program Files\3par\System Reporter) and delete

the entire directory.

7Locate and remove the inservstats.db file if the file was in a location other than the System Reporter folder. Also remove the file inservstats.db-journalif present in the

same folder.

8(Optional). In the location where you installed Apache HTTP Server, locate the htdocs directory (for example, C:\Program Files\Apache Group\Apache2\htdocs) and delete the 3par subdirectory (C:\Program Files\Apache Group\Apache2\htdocs\3par).