In each configuration above, only one embedded NIC port can have PXE enabled (any embedded NIC port is eligible), but any and all mezzanine NIC ports can be enabled whether or not an embedded NIC port is being enabled.
For more information on RBSU, see the HP
The iSCSI configuration setup feature enables you to configure a server to boot from a remote iSCSI target as part of the VC server profile.
Use the iSCSI offload feature to offload iSCSI protocol processing from the OS to the NIC. In addition to offloading TCP/IP protocol processing, it also offloads iSCSI protocol processing.
The following items are required for iSCSI offload and boot. To verify the latest requirements, see the Virtual Connect QuickSpecs on the HP website (http://www.hp.com/go/vc/manuals):
•VC 3.10 or higher firmware
•HP VC FlexFabric
•HP VC FlexFabric 20/40 F8
•HP VC
•HP VC Flex 10/10D
•The latest BIOS on a supported server.
•NIC requirements:
o HP NC551i
o HP NC553i 10Gb
•One Command OS tool
•be2iSCSI driver
•be2iSCSI Driver Update Disk for iSCSI boot installs
•iSCSI target
•DHCP server (optional)
The following features are supported:
•Full
•
•Four physical functions per port
•Up to 128 iSCSI targets per iSCSI function
•Primary/Secondary iSCSI boot path per adapter
•The iSCSI function on the adapter appears to the OS as a standard SCSI device.
•With the new iSCSI driver, no network driver is needed.
•Does not use software iSCSI initiator from the OS
Virtual Connect server profiles 172