Icon

Operational state

Meaning

(blue)

Initializing

Device is initializing.

 

 

 

Unavailable

Device is active but unable to

 

(blue)

 

provide service.

 

 

 

Degraded

Device is partially operational, but

(yellow)

 

capacity is lost.

 

 

(orange)

Misconfigured

Device has a configuration error.

 

 

 

Incompatible

Device does not match the

(orange)

 

configuration.

 

 

 

No communication

Cannot communicate with the

(orange)

 

device.

 

 

 

Missing

Device is configured but not

 

 

 

accessible.

 

Failed

Device is not operational because

 

 

of an error.

 

 

 

Corrective action

Wait until initialization is complete. (This icon should only be seen at startup.)

Attempt to re-establish connection.

Check and correct the Onboard Administrator error condition.

Correct the Virtual Connect Manager configuration attributes.

Remove the incorrect hardware. Insert the correct module.

Check the physical connections and IP address.

Insert the correct hardware module.

Reset the device or application, or replace the device.

Interconnect Bay OA Communication Status icon definitions

Icon

Operational state

Meaning

Corrective action

 

 

 

 

OK

Device is fully operational.

Failed

Cannot communicate with the

 

device.

 

 

None

Do one or more of the following:

Reset the interconnect module.

Check if the physical device is properly seated in the bay.

Check the IP address.

Virtual Connect modules 263