Port Statistic

Description

 

 

IfHCOutMulticastPkts

The total number of packets that higher-level protocols requested be

 

transmitted, and which were addressed to a multicast address at this

 

sublayer, including those that were discarded or not sent. For a MAC

 

layer protocol, this includes both Group and Functional addresses. This

 

object is a 64-bit version of ifOutMulticastPkts.

 

 

IfHCOutBroadcastPckts

The total number of packets that higher-level protocols requested be

 

transmitted, and which were addressed to a broadcast address at this

 

sublayer, including those that were discarded or not sent. This object is a

 

64-bit version of ifOutBroadcastPkts.

 

 

cosq<N>_ucast_DroppedPkts

The accumulated dropped packet count of unicast packet of the queue for

 

the specified port. For VC FlexFabric 10Gb/24-port module and VC

 

Flex-10 Enet module, the counter includes unicast and multicast data.

 

 

cosq<N>_ucast_OutBytes

The accumulated transmitted byte count of unicast packets of the queue for

 

the specified port. For VC FlexFabric 10Gb/24-port module and VC

 

Flex-10 Enet module, the counter is not supported and the value is 0.

 

 

cosq<N>_ucast_OutPkts

The accumulated transmitted packet count of unicast packets of the queue

 

for the specified port. For VC FlexFabric 10Gb/24-port module and VC

 

Flex-10 Enet module, the counter includes both unicast and multicast data.

 

 

*These statistics appear for physical uplink ports, physical downlink ports, and Flex-10 subports. All other statistics only appear for physical uplink and downlink ports.

Remote Device Information*

Description

 

 

remote_type

Type of remote device. Virtual Connect uses this information to configure

 

the link as an uplink, a stacking link, or to disable. This information is

 

based on the LLDP data sent by the device to which the port is attached.

 

 

remote_discovered_time

Time the remote device was identified, represented in seconds. This

 

information is based on the LLDP data sent by the device to which the port

 

is attached.

 

 

remote_chassis_id_type

Chassis ID subtype of the remote device

 

 

remote_chassis_id

Chassis ID value of the remote device

remote_port_id_type

Port ID subtype of the remote device

remote_port_id

Port ID value of the remote device

remote_port_desc

Port description of the remote device

remote_system_name

System name of the remote device. If the remote device is a VC-Enet

 

module, remote_system_name is the remote device's VC domain name.

remote_system_desc

Description of the remote system. If the remote device is a VC-Enet module,

 

remote_system_desc is the module's hardware description and firmware

 

revision.

 

 

remote_system_capabilities

System capabilities of the remote system, for example, repeater, bridge,

 

or router

 

 

remote_mgmt_addr_type

Management address subtype of the remote device, for example, IPv4,

 

IPv6, or DNS

 

 

remote_mgmt_addr

Management address of the remote device

*This information is only available for physical uplink and downlink ports. It is not available for Flex-10 subports.

Pluggable Module Information*

Description

 

 

 

 

identifier

Identifies the type of serial transceiver. The binary values are defined in

 

 

SFF-8472 in the Identifier [Address A0h, Byte 0] field. This field displays

 

 

an ASCII representation of those binary values.

 

 

 

 

 