Icon

Operational state

Meaning

(orange)

Incompatible

Device does not match the

 

 

(orange)

 

configuration.

 

 

 

No communication

Cannot communicate with the

(orange)

 

device.

 

 

 

Missing data

VCM is missing data about one or

(orange)

 

more blades in the multi-blade

 

server.

 

 

 

Missing

Device is configured but not

 

 

 

accessible.

 

Failed

Device is not operational because

 

 

of an error.

 

 

 

Corrective action

configuration attributes.

BIOS version level is not at a level that supports Virtual Connect.

Check the physical connections and IP address.

Check that the blades and Blade Link that comprise the multi-blade server are installed correctly and functioning properly.

Insert the correct hardware module.

Reset the device or application, or replace the device.

Server Bay OA Reported Status icon definitions

Icon

Operational state

Meaning

Corrective action

 

 

 

 

OK

Unknown

Degraded

(yellow)

Device is fully operational.

Device operational state cannot be determined.

Device is partially operational, but capacity is lost.

None

Check Onboard Administrator communication.

Check and correct the Onboard Administrator error condition.

Failed

Device is not operational because

 

of an error.

 

 

Check and correct the Onboard Administrator error condition.

Server Bay VC Status icon definitions

Icon

Operational state

Meaning

Corrective action

 

OK

Device is fully operational.

None

 

Unknown

Device operational state cannot be

Check Onboard Administrator

 

 

 

determined.

communication.

 

Disabled

Device is disabled.

Enable the component in Virtual

 

 

 

 

Connect Manager.

 

Initializing

Device is initializing.

Wait until initialization is complete.

 

(blue)

 

 

(This icon should only be seen at

 

 

startup.)

 

 

 

 

 

 

 

 

Profile pending

Device has a pending profile

(blue)

 

assignment.

 

 

 

Degraded

Device is partially operational, but

(yellow)

 

capacity is lost.

 

 

Turn server power off and apply the new profile.

Check and correct the Onboard Administrator error condition.

Misconfigured

(orange)

Incompatible

(orange)

Device has a configuration error.

Device does not match the configuration.

Correct the Virtual Connect Manager configuration attributes.

BIOS level is not at a level that supports Virtual Connect.

 

No communication

Cannot communicate with the

Check the physical connections and IP

(orange)

 

device.

address.

 

 

 

 

 

 

Virtual Connect modules 268