Restart after OA credential recovery

The state "profile recovered," is applied to servers that are powered up when VC Manager restarts after an OA credential recovery. When VC Manager detects a restart after a credential recovery, it rewrites the profile parameters for any server that is powered up, connects the server to the appropriate Ethernet networks and FC fabrics, and then puts the server and profile in the "profile recovered" state. The server and profile remain in the "profile recovered" state until the server is powered down or removed from the enclosure. This feature eliminates the power cycle requirement for a server to recover.

Additional information

The following links provide information on Virtual Connect:

HP Virtual Connect Technology website (http://www.hp.com/go/virtualconnect) o Download a free copy of HP Virtual Connect for Dummies

o Access QuickSpecs for VC modules

The QuickSpecs for each module contain information on required cabling and available cables o Access support information for Virtual Connect

HP Virtual Connect support website (http://www.hp.com/support/vc) o Download drivers and software

o Troubleshoot a problem

o Setup, install, and configure

HP Subscriber's Choice website (http://www.hp.com/go/myadvisory) to sign up for email alerts on: o Driver updates

o Software updates o Firmware updates o Customer advisories

Maintenance and troubleshooting 288