oConfigurable role operations must be delegated to one of the following roles if they are to be performed while the domain is in Maintenance Mode: Network, Storage, or Domain. Administrators logging into VCM with a Server role account while the domain is in Maintenance mode will be denied access to perform delegated operations such as exporting support files, updating firmware, configuring port monitoring, or saving or restoring domain configuration.

oIn VC 4.30/4.31, the telemetry port throughput is Enabled by default. You must do the following to add a fresh VC 4.30/4.31 installation to your existing VCDG:

3.30-3.70 VCDG with statistics throughput disabled—Clear the Enable Throughput Statistics check box on the Ethernet Settings (Advanced Settings) screen ("Ethernet Networks (Advanced Settings)" on page 97), or run the following VCM CLI command:

set statistics-throughput Enabled=false

3.30-3.70 VCDG with statistics throughput enabled—Add the domain as is. No change is required.

oIn VC 4.30/4.31, the VLAN Capacity is set to Expanded by default. You must do the following to add a fresh VC 4.30/4.31 installation to your existing VCDG:

3.30-3.70 with Legacy VLAN VCDG—You cannot add the domain. Select a different VCDG.

3.30-3.70 with Enhanced VLAN VCDG—Add the domain as is. No change is required.

A server profile migration of a SAN-booted server between enclosures is not supported for SAN-boot from a Direct-Attached 3PAR array.

Virtual Connect documentation

The following Virtual Connect documentation is available on the HP website (http://www.hp.com/go/vc/manuals):

HP Virtual Connect for c-Class BladeSystem User Guide

This guide provides details for the Virtual Connect GUI, including descriptions of screen contents and steps to set up domains, profiles, networks, and storage.

HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide

This guide provides hardware installation and configuration information for initial setup of a Virtual Connect solution. The guide also provides Virtual Connect module component and LED descriptions and guidelines for module installation and upgrades.

HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem User Guide

This guide provides information for using the Virtual Connect Command Line Interface, including use scenarios and complete descriptions of all subcommands and managed elements.

HP Virtual Connect Ethernet Cookbook: Single and Multiple Domain (Stacked) Scenarios

This guide helps new Virtual Connect users understand the concepts of and implement steps for integrating Virtual Connect into a network. The scenarios in this guide vary from simplistic to more complex while covering a range of typical building blocks to use when designing Virtual Connect solutions.

HP Virtual Connect Fibre Channel Networking Scenarios Cookbook

This guide details the concepts and implementation steps for integrating HP BladeSystem Virtual Connect Fibre Channel components into an existing SAN fabric. The scenarios in this guide are simplistic while covering a range of typical building blocks to use when designing a solution.