Interconnect Bay Summary (Details) Enet

Click the Details tab to display information on the following items:

MAC Address ("MAC address settings" on page 178)

IGMP Multicast ("Ethernet Bay Summary (IGMP Multicast Groups) screen" on page 245)

Name Server ("Ethernet Bay Summary (Name Server) screen" on page 246)

FIP Snooping ("Interconnect Bay Summary (FIP Snooping) Enet" on page 247)

Ethernet Bay Summary (MAC Address Table) screen

This screen shows the MAC addresses that have been seen on the ports of the VC-Enet module. If a network is assigned to the port, the network name appears. If a shared network is assigned to the port, the network name and VLAN ID appear. If a LAG has formed with the uplink ports, the LAG ID appears.

The following table describes the columns within the MAC Address Table.

Column

Description

 

 

 

 

Port

Label of the port on which the MAC address was seen

 

 

Flex-10 downlinks ports are displayed as dx:vx, for example, d1:v1

 

 

 

 

MAC Address

MAC address that was seen

 

Type

Identifies how the address was seen (Learned or Other)

 

LAG

Identifies the group of ports that have been aggregated together to form an

 

 

802.3ad Link Aggregation Group. This ID is unique only within a single

 

 

VC-Enet module, meaning the same LAG ID can be used on different VC-Enet

 

 

modules, but it is only meaningful for ports within the same VC-Enet module.

 

 

 

 

Internal VLAN ID

Internal VLAN ID used by Virtual Connect Manager

 

Network Name

The name of the network associated with this port (downlink ports only)

 

LAG membership table

Relates the LAG IDs and uplink ports, which can help you understand the

 

 

information in the MAC address table

 

 

Virtual Connect modules 244