Troubleshooting

 

 

 

 

Identifying LCD-Indicated Conditions

Table 2-1. Chassis Codes for J6000 Workstations

 

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

INI

3n07

SYS BD

CPUn invoke LDB

CPU n is starting the low-level debugger.

 

 

 

 

 

FLT

3n09

SYS BD

bad sys mde byte

CPU n detected an unsupported system

 

 

 

 

mode.

 

 

 

 

 

WRN

3n1A

SYS BD

hversion mismtch

Stable store hardware version doesn’t

 

 

 

 

match system.

 

 

 

 

 

TST

3n1B

SYS BD

chck model strng

Check model string with version in stable

 

 

 

 

store.

 

 

 

 

 

WRN

3n1B

SYS BD

model str msmtch

Model string doesn’t match that in stable

 

 

 

 

store.

 

 

 

 

 

FLT

3n1B

SYS BD

fatal model str

Error reading model string from stable

 

 

 

 

store.

 

 

 

 

 

TST

3n1C

SYS BD

test software ID

Check LANIC address.

 

 

 

 

 

WRN

3n1C

SYS BD

update sw ID

Update LANIC address.

 

 

 

 

 

FLT

3n1C

SYS BD

update sw ID err

Error updating LANIC address.

 

 

 

 

 

INI

3n2s

SYS BD

Invoke LDB: s

CPU n is awaiting the low-level debugger

 

 

 

 

for s more seconds.

 

 

 

 

 

TST

3nBC

IO BD

test sys clocks

CPU n is verifying processor clocks with

 

 

 

 

the real-time clock.

 

 

 

 

 

INI

3nBC

SYS BD

init sys clocks

CPU n has initialized the processor clocks.

 

 

 

 

 

FLT

3nBC

IO BD

RTC tick timeout

The real-time clock is ticking too slowly or

 

 

 

 

not at all.

 

 

 

 

 

TST

3nCD

SYS BD

check defaults

CPU n is initializing stable store values to

 

 

 

 

system defaults.

 

 

 

 

 

INI

3nCD

SYS BD

init defaults

CPU n finished initializing stable store

 

 

 

 

values.

 

 

 

 

 

FLT

3nCD

SYS BD

init EEPROM err

CPU n detected an error writing to stable

 

 

 

 

store.

 

 

 

 

 

FLT

3nEC

SYS BD

bad sys config

CPU n detected an illegal CPU board

 

 

 

 

configuration.

 

 

 

 

 

FLT

3nF4

SYS BD

EEPROM boot limt

CPU n detected a fatal error writing the

 

 

 

 

EEPROM.

 

 

 

 

 

FLT

3nFC

SYS BD

bad sys bd id

CPU n cannot identify CPU board.

 

 

 

 

 

TST

4n00

SYS BD

CPUn start lst

CPU n is starting its late (with memory)

 

 

 

 

self-tests.

 

 

 

 

 

Chapter 2

49

Page 49
Image 49