Troubleshooting

Identifying LCD-Indicated Conditions

Table 2-1. Chassis Codes for J6000 Workstations

Ostat

Code

FRU

Message

Description

 

 

 

 

 

FLT

7309

DIMM

insufficient mem

Insufficient error-free memory to

 

 

 

 

continue.

 

 

 

 

 

FLT

730C

SYS BD

mem intrlv fail

Memory interleave generation failed.

 

 

 

 

 

INI

730F

SYS BD

mem config done

Main memory configuration complete.

 

 

 

 

 

TST

7400

DIMM

non-dest mem tst

Starting non-destructive memory test.

 

 

 

 

 

TST

740F

DIMM

non-dst tst done

Non-destructive memory test complete.

 

 

 

 

 

INI

7500

SYS BD

memory reset

Resetting memory system.

 

 

 

 

 

WRN

7501

SYS BD

mem log clr warn

Memory error logs didn’t clear on first try.

 

 

 

 

 

FLT

7502

SYS BD

mem err log fail

Firmware could not clear memory error

 

 

 

 

logs.

 

 

 

 

 

TST

7600

DIMM

dest mem test

Starting the destructive memory test.

 

 

 

 

 

WRN

7601

DIMM

mem init only

Skip the test, just initialize memory to

 

 

 

 

save time.

 

 

 

 

 

TST

7602

DIMM

tst 1st mem page

Starting 3-pass test of first memory page.

 

 

 

 

 

TST

7603

DIMM

tst rest of mem

Starting 3-pass test of the rest of memory.

 

 

 

 

 

TST

7604

DIMM

start 1st pass

Starting 1st pass of memory test (write

 

 

 

 

pseudorandom sequence).

 

 

 

 

 

TST

7605

DIMM

1st pass x%

First pass is x% complete.

 

 

 

 

 

TST

7606

DIMM

start 2nd pass

Starting 2nd pass of memory test (verify

 

 

 

 

pseudorandom sequence, write inverse).

 

 

 

 

 

TST

7607

DIMM

2nd pass x%

Second pass is x% complete.

 

 

 

 

 

TST

7608

DIMM

start 3rd pass

Starting 3rd pass of memory test (verify

 

 

 

 

inverse sequence).

 

 

 

 

 

TST

7609

DIMM

3rd pass x%

Third pass is x% complete.

 

 

 

 

 

TST

760A

DIMM

start mem init

Starting memory initialization. (Initialize

 

 

 

 

to zero to set ECC.)

 

 

 

 

 

TST

760B

DIMM

mem init x%

Memory initialization is x% complete.

 

 

 

 

 

WRN

760C

DIMM

repeat dest test

Re-execute destructive test for hardware

 

 

 

 

troubleshooting.

 

 

 

 

 

FLT

760D

DIMM

mem code cpy err

Firmware tried to copy code from ROM to

 

 

 

 

memory, but the copy didn’t match the

 

 

 

 

original.

 

 

 

 

 

FLT

7610

DIMM

ECC wrt/read err

Writing and reading back good data

 

 

 

 

caused memory ECC error.

 

 

 

 

 