| Troubleshooting | |
|
| Using the System Board LEDs for Troubleshooting | ||
Table |
|
|
| |
|
|
|
|
|
Blink | LED Blink Sequence |
| Description |
|
Sequence | (black dot represents 0.1 second LED on; white dot |
|
| |
Number | is 0.1 second LED is off) |
|
|
|
|
|
|
|
|
System Controller Error Blink Sequences |
|
|
| |
|
|
|
|
|
4 | ● ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ |
| System controller |
|
|
|
| shut off power to |
|
|
|
| the system because |
|
|
|
| the ambient |
|
|
|
| temperature |
|
|
|
| exceeded 60˚C or |
|
|
|
| 140˚F. |
|
|
|
|
|
|
5 | ● ● ● ● ● ● ● ● ● ❍ |
| System controller |
|
|
|
| detects a fan |
|
|
|
| failure. If this |
|
|
|
| happens you need |
|
|
|
| to read the message |
|
|
|
| in the LCD on the |
|
|
|
| front of the |
|
|
|
| workstation. |
|
|
|
|
|
|
6 | ● ❍ ● ❍ ● ❍ ❍ ❍ ❍ ❍ |
| System controller is |
|
|
|
| reporting an error. |
|
|
|
|
|
|
Troubleshooting with System Board LEDs
This section explains what to do when you see the LEDs on your system board in a
Table 2-4. Solutions for the Non-Default LED States
LED Name1 |
| Solution |
| State |
|
|
|
|
VRM1 | OFF | If the following solutions do not bring this LED back |
|
| on, replace VRM1 board. |
|
| • Swap VRM cards to determine if VRM1 is bad |
|
| • Determine that the power cable to the system is |
|
| plugged in |
|
| • Check that the power button has been pressed on |
|
| • |
|
| • Check that the VRM1 connector cable is properly |
|
| plugged in |
|
|
|
Chapter 2 | 71 |