Troubleshooting

 

 

 

 

Identifying LCD-Indicated Conditions

Table 2-1. Chassis Codes for J6000 Workstations

 

 

 

 

 

 

Ostat

Code

FRU

Message

Description

 

 

 

 

 

WRN

CB73

SYS BD

TOC occurred

A Transfer of Control caused entry to

 

 

 

 

PDCE_CHECK (the firmware trap

 

 

 

 

handler).

 

 

 

 

 

FLT

CB9r

IO BD

Error on roper

An error was detected on rope r.

 

 

 

 

 

FLT

CB99

SYS BD

seed IVA handler

PDC_SEED_ERROR triggered an HPMC.

 

 

 

 

 

FLT

CB9A

SYS BD

HPMC overwrite

Firmware is overwriting PIM data from a

 

 

 

 

previous HPMC.

 

 

 

 

 

OFF

CBA1

SYS BD

AIOC int dat err

I/O controller internal error.

 

 

 

 

 

OFF

CBA2

IO BD

EtoA rope perr

Parity error between I/O controller and

 

 

 

 

Rope-to-PCI bridge.

 

 

 

 

 

OFF

CBA3

SYS BD

access invld TLB

An invalid I/O TLB entry was accessed.

 

 

 

 

 

OFF

CBA4

IO BD

EtoA rp cmd perr

Command parity error between I/O

 

 

 

 

controller and Rope-to-PCI bridge.

 

 

 

 

 

OFF

CBA5

IO BD

CDF timeout

Rope Command/Data FIFO is backed up.

 

 

 

 

 

OFF

CBA6

IO BD

R2PCI resp tmout

Rope-to-PCI bridge timed out. Could be a

 

 

 

 

failure of the PCI card, rope, or R2PCI

 

 

 

 

bridge.

 

 

 

 

 

OFF

CBA7

IO BD

Unknown AIOC err

Unknown I/O controller error.

 

 

 

 

 

OFF

CBB1

IO BD

PCI timeout

A PCI card requested the bus but failed to

 

 

 

 

use it.

 

 

 

 

 

OFF

CBB2

IO BD

PCI timeout; OV

More than once aPCI card requested the

 

 

 

 

bus but failed to use it.

 

 

 

 

 

OFF

CBB3

IO BD

R2PCI intrnl err

Rope-to-PCI bridge internal error.

 

 

 

 

 

OFF

CBB4

IO BD

R2PCI int err;OV

Multiple Rope-to-PCI bridge internal

 

 

 

 

errors.

 

 

 

 

 

OFF

CBB6

IO BD

PCI data req err

PCI bus data requestor error: R2PCI

 

 

 

 

detected PERR# assertion.

 

 

 

 

 

OFF

CBB8

IO BD

PCI D req err;OV

Rope-to-PCI bridge detected multiple

 

 

 

 

PERR# assertions.

 

 

 

 

 

OFF

CBBA

IO BD

PCI data par err

PCI bus data parity error.

 

 

 

 

 

OFF

CBBC

IO BD

PCI Dpar err;OV

Multiple PCI bus data parity errors.

 

 

 

 

 

OFF

CBBE

IO BD

R2PCI intrnl err

Error in R2PCI internal data to PCI bus.

 

 

 

 

 

OFF

CBC0

IO BD

R2PCI int err;OV

Multiple R2PCI internal data to PCI bus

 

 

 

 

errors.

 

 

 

 

 

Chapter 2

63

Page 63
Image 63
HP visualize J6000 work stations manual Transfer of Control caused entry to