Configuring the Autoloader

The Configuration menu provides access to the following autoloader configuration options:

Resetting the autoloaderSetting SCSI IDsSetting autoloader mode to Circular/AutoloadUpdating firmware

To access the Configuration menu from the Home Screen or main menu, press the [+] or [-] button until Configuration appears on the top line of the LCD screen. Press the [Enter] button and then [+] or [-] to access the available options. Press the [Enter] button to execute the displayed menu option.

Resetting the Autoloader

This option resets the autoloader robotics and the tape drive within the autoloader, forces a new cartridge inventory, and clears any current error condition.

Note

This option is primarily used if the autoloader is in an error state.

 

 

To access this option, follow these steps:

1.From the Home Screen or main menu, press the [+] or [-] button until Configuration appears on the top line of the LCD screen.

2.Press [Enter] to select.3.Press the [+] or [-] button until Reset appears on the LCD screen.4.Press the [Enter] button to reset the autoloader.

After initialization, the autoloader returns to normal operation and displays the

Home screen.

40 Autoloader Administration