Table 5 Error Codes
Error Code | Description | Details |
|
|
|
3 0 83 | Inventory not valid. | The cartridge inventory is not valid because of |
|
| manual changes or previous fatal errors. Update |
|
| the inventory using the |
|
| Configuration menu. See page 38 or power |
|
| cycle. |
|
|
|
3 0 84 | Source empty. | There is no cartridge in the location where a |
|
| cartridge move was issued. |
|
|
|
3 0 85 | Destination full. | The location where a cartridge move was issued |
|
| already contains a cartridge. |
|
|
|
3 0 86 | Mail slot access rejected. | User attempted to access the mail slot, but media |
|
| removal was prevented by the host. |
|
|
|
3 0 87 | Operation timeout. | A command did not complete in the required |
|
| amount of time. |
|
|
|
3 0 88 | Communications error during | Cycle power on the autoloader and attempt the |
| operation again. If the error recurs, contact your | |
|
| technical support representative. |
|
|
|
3 0 89 | System test timeout. | There was a communication timeout between the |
|
| drive and loader during the System Test. |
|
|
|
3 0 8F | Recovered loader error. | Loader error recovery successful. Your diagnostic |
|
| tool can provide details of the original loader |
|
| error. |
|
|
|
3 0 90 | Mechanical Initialization failure. | The robotics were not able to move to the safe |
|
| mechanical initialization position. Manual |
|
| intervention is necessary. |
|
|
|
3 0 91 | Inventory scan failure. | Fatal robotic error occurred during the inventory |
|
| scan. |
|
|
|
3 0 92 | Preposition failed. | Belt positioning error occurred during |
|
| 'Preposition' command. |
|
|
|
3 0 93 | Cartridge load error. | A failure occurred while trying to load a |
|
| cartridge from the drive to its slot. |
|
|
|
Chapter 4 | Diagnostics and Troubleshooting 67 |