Table 5 Error Codes

Error Code

Description

Details

 

 

 

3 0 83

Inventory not valid.

The cartridge inventory is not valid because of

 

 

manual changes or previous fatal errors. Update

 

 

the inventory using the Re-inventory option in the

 

 

Configuration menu. See page 38 or power

 

 

cycle.

 

 

 

3 0 84

Source empty.

There is no cartridge in the location where a

 

 

cartridge move was issued.

 

 

 

3 0 85

Destination full.

The location where a cartridge move was issued

 

 

already contains a cartridge.

 

 

 

3 0 86

Mail slot access rejected.

User attempted to access the mail slot, but media

 

 

removal was prevented by the host.

 

 

 

3 0 87

Operation timeout.

A command did not complete in the required

 

 

amount of time.

 

 

 

3 0 88

Communications error during

Cycle power on the autoloader and attempt the

 

loop-back.

operation again. If the error recurs, contact your

 

 

technical support representative.

 

 

 

3 0 89

System test timeout.

There was a communication timeout between the

 

 

drive and loader during the System Test.

 

 

 

3 0 8F

Recovered loader error.

Loader error recovery successful. Your diagnostic

 

 

tool can provide details of the original loader

 

 

error.

 

 

 

3 0 90

Mechanical Initialization failure.

The robotics were not able to move to the safe

 

 

mechanical initialization position. Manual

 

 

intervention is necessary.

 

 

 

3 0 91

Inventory scan failure.

Fatal robotic error occurred during the inventory

 

 

scan.

 

 

 

3 0 92

Preposition failed.

Belt positioning error occurred during

 

 

'Preposition' command.

 

 

 

3 0 93

Cartridge load error.

A failure occurred while trying to load a

 

 

cartridge from the drive to its slot.

 

 

 

Chapter 4

Diagnostics and Troubleshooting 67

Page 67
Image 67
HP vs80 manual Configuration menu. See page 38 or power