Control panel message | Description | Recommended action | |
|
|
|
|
Memory error during POST execution of the | 1. | Reboot the workstation. | |
cleanup | Management Engine (ME) BIOS Extensions | 2. | Unplug the power cord, |
| option ROM | ||
|
|
| memory modules, and reboot the |
|
|
| workstation. |
|
| 3. | If the memory configuration was recently |
|
|
| changed, unplug the power cord, restore |
|
|
| the original memory configuration, and |
|
|
| reboot the workstation. |
|
| 4. | If the error persists, replace the system |
|
|
| board. |
|
|
|
|
MEBx selection or exit resulted in a setup | 1. | Reboot the workstation. | |
| failure. | 2. | Unplug the power cord, |
|
| ||
|
|
| memory modules, and reboot the |
|
|
| workstation. |
|
| 3. | If the memory configuration was recently |
|
|
| changed, unplug the power cord, restore |
|
|
| the original memory configuration, and |
|
|
| reboot the workstation. |
|
| 4. | If the error persists, replace the system |
|
|
| board. |
|
|
|
|
BIOS information passed to the MEBx resulted | 1. | Reboot the workstation. | |
| in a failure. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
MEBx operation experienced a hardware | 1. | Reboot the workstation. | |
| error during communication with ME. | 2. | If the error persists, update to the latest |
|
| ||
|
|
| BIOS version. |
|
| 3. | If the error still persists, replace the |
|
|
| system board. |
|
|
|
|
Invalid Electronic Serial Number | Electronic serial number has become | 1. | Run Computer Setup. If Setup already |
| corrupted. |
| has data in the field or will not allow |
|
|
| the serial number to be entered, |
|
|
| download from http://www.hp.com |
|
|
| and run SP5572.EXE (SNZERO.EXE). |
|
| 2. | Run Computer Setup and try to enter |
|
|
| serial number under Security, System ID, |
|
|
| then save changes. |
|
|
|
|
Network Server Mode Active and No | Keyboard failure while Network Server Mode | 1. | Reconnect keyboard with workstation |
Keyboard Attached | enabled. |
| turned off. |
|
| 2. | Check connector for bent or missing pins. |
|
| 3. | Ensure that none of the keys are |
|
|
| depressed. |
|
| 4. | Replace keyboard. |
|
|
|
|
ENWW | POST numeric codes and text messages 113 |