Appendix B • Installing the indoor equipment using dial- up commissioning
92 1033295-0001 Revision 2
10. Sel ect the Manual fine pointing mode radio button.
11. Sel ect Start Test. Adjust the antenna to achieve maximum
transmit isolation.
12. When the unit consistently passes the manual transmit test,
bolt the antenna securely before going to Step13.
13. After the antenna is bolted, select Stop Test. See Figure81.
14. Then select the Autom atic radio button and select Start Test
to start the automatic ACP test. See Figure 82.
15. Make sure the test passes.
16. Sel ect Exit after passing the test.
Figure 81: Manual cross-pol passed; select Stop Test
Figure 82: Auto cross-pol