Appendix C • Installing the DW6000 using Installer Console
1033295-0001 Revision 2 119
The Final Test Menu The Final Test Menu is not used by installers. It is used at the
factory to ensure the various DW6000 components are functional.
The menu is shown below.
Other options This section describes some other options in the Main Menu.
Display active routing table Menu Option (d) displays the current data in the Active
Routing Table, shown in Figure111. This data is read-only.
Reset history Menu Option (h) displays the reset history for the DW6000 as
shown in Figure 112. One of the most recent 8 reset logs may be
displayed. Index 0 is the most recently logged reset.
This data is read-only.
Note that you reset the DW6000 by typing rr at the Main Menu
prompt and pressing Enter. You can force the DW6000 to
download new keys and new software by typing rd and pressing
Enter.
Reading factory information Option (g) displays read-only information from the manufacturer.
This option automatically returns to the Final Test menu.
Final Test Menu:
(a) LED Test Pattern
(b) Ethernet Ports Test
(c) Modem Signal Test
(d) USB Port Test
(g) Factory Information Read
(z) Return to Main Menu
Figure 110: Final Test Menu
Main Menu (<?/CR> for options): d
Active Routing Table:
Entry Destination Network DW6000 Address
Subnet Mask
Main Menu (<?/CR> for options):
Figure 111: Active Routing Table display
Time of Reset : THU JAN 01 05:47:35 1970
Asserted at : t=tInterface ../../../source/sd/cim.c#1918:
Reset Type : Valid Software Reset
Reset Reason : Manual reboot via Install Console rr command
Figure 112: Reset history