Appendix C • Installing the DW6000 using Installer Console
102 1033295-0001 Revision 2
2. LAN LED comes on within 30 seconds to indicate LAN
connectivity is detected.
3. Power LED starts blinking to indicate that the unit is not
commissioned and therefore is running fallback.bin and not
main.bin.
Obtain IP address and test
Ethernet connection
1. Restart the PC so that the DW6000 assigns it an IP address.
Or use the command ipconfig /renew from a DOS
command line prompt.
2. The embedded DHCP server assigns IP address =
192.168.0.2 to the PC. The DW6000 Address is set to
192.168.0.1.
Confirm the PC can communicate with the DW6000 over the
Ethernet connection. Enter Ping <192.168.0.1> at a DOS
prompt. Figure 92 shows a successful attempt, and Figure93
shows an unsuccessful attempt. If the client fails to ping the
host, issues exist with the network hardware or configuration.
Note: In countries outside North America, the DW6000 may be
plugged, with a physical adapter, directly into a 220 V outlet.
Different countries may have different standards and requirements.
Note: Whenever the LEDs do not function properly as described
below, check to be sure you have the correct power supply, PN
1031105-0001.
Figure 92: Successful ping
Figure 93: Failed ping