2.Perform the following checks, one by one, until you have isolated the problem FRU (refer to “Parts/Test Point Locations” on page
Check all system board jumper positions.
Check all adapter card jumper positions.
Check all adapter card switch settings.
Check all device jumper positions.
Check all cables and connectors for proper installation.
If the jumpers, switch settings, and voltages are correct, return here and continue:
3. Remove or disconnect the following, one at a time:
a.
b.External devices
c.Any adapters
d.Modem card
e. DIMMs | (Remove all but one DIMM. Swap last DIMM with known |
good | DIMM) |
f.Zip Drive
g.
h.Diskette drive i. Hard disk drive
4.
5. Repeat steps 1 through 4 until you find the failing device or adapter.
If | the | symptom changes, | go to “Index of | Symptoms, | Messages, | Error | Codes, | |||||
or Beeps” on page | check | procedure | for | the | last | item | tested. | |||||
Replace | the last item tested if | the | system | operates | normally after | removing | ||||||
the | last | item. |
|
|
|
|
|
|
|
|
|
|
Note: | If | you are unable to find | a check procedure that corresponds to the | |||||||||
| device or error code, you | either | have | an | IBM | device | with its own | |||||
| service manual or a | device | not supported | by | IBM | diagnostic | tests. |
If all devices and adapters have been removed, and the problem remains:
1.Remove all cables from connectors on the system board except the power supply and switch cables. See “System Board
on page | ||
for | connector locations. | |
2. Remove all | but one DIMM from sockets. Replace last DIMM with | |
known | good | DIMM. |
3.
Check