Command Line Options
To enter PC-Doctor commands:
Note: Before beginning, ensure that Suspend Timer is disabled in the
Setup Utility.
1. Install the Diagnostics and Utilities CD in the CD/DVD-ROM drive.
2. Power-off, then power-on the system unit.
3. Do not press F1 during POST.
4. If any POST errors appear after POST, make a note of the errors and
press the Esc key.
5. When the “Aptiva Diagnostics and Utilities Menu” screen is displayed,
type: zero for a DOS prompt, then change the DOS prompt to G: or the
drive letter designated for the CD/DVD-ROM.
6. Type CD\PCDR to get the the PCDR directory.
7. Type PCDR/XX (where /XX represents one of the following from the list
below) then press Enter.
Command Action
/AN Enables automatic testlog numbering. A sequential number
will be added to testlogs automatically. This number is stored
in the file PCDR.NUM, which can be edited using the text
editor. PC-Doctor will automatically add a testlog number if the
file PCDR.NUM exists. To disable this feature, you must
delete the PCDR.NUM file.
/BA:xx Start batch mode testing of overlay number "xx". The overlay
number must be in the range of 1- 10. For this switch to be
useful, it should be combined with the "/PR:nnnn" switch and
possibly also the /EO and /HE switches. At the end of batch
mode testing, PC-Doctor returns with an ERRORLEVEL that is
set to 0 for no errors, 1 if any tests failed, or 2 if testing was
aborted.
/DJ Direct Joystick I/O. This will force PC-Doctor to read joystick
status and position directly from the hardware.
/EO Log error only. If selected, PC-Doctor will only log tests that
produce a FAILED result. You can use this switch to bypass
PASSED and N/A test results in order to produce shorter test
logs.
/HE Enables halt-on-errors mode. If PC-Doctor encounters a failed
diagnostic test, it asks the user if it should continue or abort
testing.
Diagnostic Aids 3-9