010(continued)
DOES THE SYSTEM CONFIGURATION REPORT CORRECTLY IDENTIFY
THE DEVICES INSTALLED IN THE SYSTEM UNIT?
Yes No
011
The System Configuration Report shows only those devices
supported by the Diagnostics and Utilities CD and only
factory-installed devices for the model you are servicing.
If a device is missing from the list and is not factory installed, refer
to the service manual provided for that device. (Refer to the
Appendix B, “Model/Monitor Configurations and FRU Part Numbers”
on page B-1 to determine the factory-installed devices in the model
you are servicing.)
If a factory-installed drive device or adapter card is not listed in the
System Configuration Report, return to “Start” on page 2-2 and test
the device. If the device can not be tested, replace the device, then
the system board.
012
Select Diagnostics Menu from the menu.
Select Easy Test Diagnostics from the menu.
DOES THE EASY TEST DIAGNOSTICS FINISH WITHOUT ERROR
CODES?
Yes No
013
If the last test stops and you cannot continue, first make sure all
switches, power connectors, cables, and jumpers are set correctly
and show the correct voltages and continuity.
Make note of any messages, error codes, beeps, or new symptoms.
Go to “Index of Symptoms, Messages, Error Codes, or Beeps” on
page 2-9.
014
The Easy Test Diagnostics did not detect a failure. If the system still
displays a failure:
Check all adapter card jumper settings.
Check all adapter card switch settings.
(Step 014 continues)
Check Procedures 2-7