Intel SR2500AL manual Replacing the Control Panel

Models: SR2500AL

1 210
Download 210 pages 25.57 Kb
Page 111
Image 111

12.Connect all power cables to the server board.

13.Install the fan module assembly. For instructions, see “Replacing a Fan Module”.

14.Install the large air baffle. For instructions, see “Installing the Large Air Baffle”.

15.Install the server system cover. For instructions, see “Installing the Server System Cover”.

16.Plug all peripheral devices and the AC power cable(s) into the server.

Replacing the Control Panel

The steps for replacing the standard control panel and the Intel® Local Control Panel are nearly identical. Use the steps below for both varieties of the control panel. Where necessary, differences between the two control panels are noted.

Your server must be operated with a control panel installed.

Caution: The control panel is NOT hot swappable. Before removing or replacing the control panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”.

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”.

4.Remove the server system cover. For instructions, see “Removing the System Cover”.

Intel® Server System SR2500AL User’s Guide

89

Page 111
Image 111
Intel SR2500AL manual Replacing the Control Panel