Intel SR2500AL manual Recovery Jumpers, CMOS Clear, Password Clear, BMC Force Update Mode

Models: SR2500AL

1 210
Download 210 pages 25.57 Kb
Page 32
Image 32
CMOS Clear

BMC Force

Update Mode

2

3

J1D2

 

Disable

Password

2

Enable

Reset

3

 

 

J1D1

2

3

J1D3

Clear

CMOS

TP02080

Jumper Name

Jumper Purpose

 

 

CMOS Clear

If pins 2-3 are jumpered, the CMOS settings will be cleared on the next

 

reset. These pins should be jumpered on 1-2 for normal operation.

 

 

Password Clear

If pins 2-3 are jumpered, administrator and user passwords will be cleared

 

on the next reset. These pins should be jumpered on 1-2 for normal

 

operation.

 

 

BMC Force Update Mode

If pins 2-3 are jumpered, BMC Force Update Mode is enabled. These pins

 

should be jumpered on 1-2 for normal operation.

 

 

 

Figure 5. Recovery Jumpers

10

Intel® Server System SR2500AL User’s Guide

Page 32
Image 32
Intel SR2500AL manual Recovery Jumpers, CMOS Clear, Password Clear, BMC Force Update Mode