Intel SR2500AL manual Replacing a Fan Module, Replacing a Redundant Fan Module

Models: SR2500AL

1 210
Download 210 pages 25.57 Kb
Page 113
Image 113

8.Install the server system cover. For instructions, see “Installing the Server System Cover”.

9.(Optional) Install the front bezel. For instructions, see “Installing the Front Bezel”.

10.Plug all peripheral devices and the AC power cable(s) into the server.

Replacing a Fan Module

Replacing a Redundant Fan Module

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”.

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the server system cover. For instructions, see “Removing the System Cover”.

4.Remove the processor air duct. For instructions, see “Removing the Processor Air Duct”.

5.Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly”.

6.Remove the optical drive cable if installed.

7.Remove the bridge board. For instructions, see Figure 61 “Removing the Bridge Board from the Server System” on page -71.

8.Remove the large air baffle. For instructions, see “Removing the Large Air Baffle”.

9.Disconnect the fan cables from the mid-plane.

Intel® Server System SR2500AL User’s Guide

91

Page 113
Image 113
Intel SR2500AL manual Replacing a Fan Module, Replacing a Redundant Fan Module