14.Install the bridge board. For instructions, see Figure 64 “Installing the Bridge Board into the Server System” on page
15.Install the optical drive cable (optional).
16.Install the PCI riser assembly. For instructions, see “Installing the PCI Riser Assembly”.
17.Install the processor air duct. For instructions, see “Installing the Processor Air Duct”.
18.Install the server system cover. For instructions, see “Installing the Server System Cover”.
19.Plug all peripheral devices and the AC power cable(s) into the server.
Replacing a Fixed Fan Module
1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”.
2.Power down the server and unplug all peripheral devices and the AC power cable(s).
3.Remove the server system cover. For instructions, see “Removing the System Cover”.
4.Remove the processor air duct. For instructions, see “Removing the Processor Air Duct”.
5.Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly”.
6.Remove the optical drive cable if installed.
7.Remove the bridge board. For instructions, see Figure 61 “Removing the Bridge Board from the Server System” on page
8.Remove the large air baffle. For instructions, see “Removing the Large Air Baffle”.
9.Disconnect the fan cables from the
Intel® Server System SR2500AL User’s Guide | 93 |