Replacing a Fixed Fan

6.Install the server system cover. For instructions, see “Installing the Server System Cover”.

Replacing a Fixed Fan

Caution: The system fans are NOT hot swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Note: The fans that are integrated into the power supply cannot be replaced separately. If one of the fans in the power supply fails, the power supply must be replaced.

The system fans at the front of the server system can be individually replaced if one of them fails. Use the steps below to replace a fan.

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”.

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the server system cover. For instructions, see “Removing the System Cover”.

4.Remove the fan module assembly. For instructions, see “Replacing a Fan Module”.

5.There are no screws to loosen. Remove the fan from the fan module (see letter “A” in the figure below).

3

2

1

A

Figure 87. Removing a Fan from the Fixed Fan Module

6.Position the replacement fan so the connector on the fan is at the right and pointing down.

7.With the fan oriented correctly, insert the fan into the fan module (see letter “A” in

the figure below), and snap in place.