In addition to the beep codes above, additional beep codes are provided if an Intel® Remote Management Module is installed. The Intel® Remote Management Module provides the following additional beep codes.

Table 10. Error Beep Codes Generated by Intel® Remote Management

Module

Number of

Reason for Beeps and Action to Take

Beeps

 

 

 

1

Control panel CMOS clear has been initiated.

 

 

1-5-1-1

Processor failure. Reseat or replace the failed processor.

 

 

1-5-2-1

No processor is installed or the CPU 1 socket is empty. Reseat or replace

 

the failed processor.

 

 

1-5-2-3

Processor configuration error or CPU 1 socket is empty. Reseat or replace

 

the failed processor. In a two-processor system, make sure the processors

 

are identical.

 

 

1-5-2-4

Front-side bus select configuration error.

 

 

1-5-4-2

DC power unexpectedly lost.

 

 

1-5-4-3

Chipset control failure.

 

 

1-5-4-4

Power control failure.

 

 

Intel® Server System SR2500AL User’s Guide