Figure 81. Removing the Redundant Fan Module

10.Remove the fan module assembly by releasing the blue retention mechanism (see letter “A” in the figure below), sliding the assembly to the left (see letter “B”), and lifting the assembly off of the standoff and out of the system (see letter “C”).

A

B

C

B

C

Figure 81. Removing the Redundant Fan Module

11.Install the replacement fan module assembly by lowering it over the standoff (see letter “A” in the figure below), and sliding the assembly to the right (see letter “B”).

B

A

B

A

Figure 82. Installing the Redundant Fan Module

12.Connect the fan cables to the mid-plane.

13.Install the large air baffle. For instructions, see “Installing the Large Air Baffle”. Re-route cables through the air baffle as necessary.