Intel SR2500AL manual Removing the Intel RMM and Intel RMM NIC, the Server System

Models: SR2500AL

1 210
Download 210 pages 25.57 Kb
Page 92
Image 92
Removing the Intel® RMM and Intel® RMM NIC

Removing the Intel® RMM and Intel® RMM NIC

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”.

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the server system cover. For instructions, see “Removing the System Cover”.

4.Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly”.

5.Remove the Intel® RMM board from the server board (see letter “A” in the figure below).

6.Remove the Intel® RMM NIC module from the server board (see letter “B” in the figure below).

7.Remove the standoffs from the server board (see letter “C” in the figure below).

8.Install the Intel® RMM NIC module cover into the system back panel (see letter “D” in the figure below).

A

B

Figure 60. Removing the Intel® RMM and the Intel® RMM NIC Module from C

D

AF000744

Figure 60. Removing the Intel® RMM and the Intel® RMM NIC Module from

the Server System

9.Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly”.

10.Install the processor air duct. For instructions, see “Installing the Processor Air Duct”.

11.Install the server system cover. For instructions, see “Installing the Server System Cover”.

12.Plug all peripheral devices and the AC power cable(s) into the server.