Replacing the Power Distribution Module

Replacing the Power Distribution Module

To replace the power distribution module, use the following instructions.

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”.

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the server system cover. For instructions, see “Removing the System Cover”.

4.Remove the large air baffle. For instructions, see “Removing the Large Air Baffle”.

5.Remove the fan module assembly. For instructions, see “Replacing a Fan Module”.

6.Disconnect all power cables from the server board, backplane, and mid-plane.

7.Remove the hot-swap power supply/supplies. For instructions, see “Replacing the Power Supply”.

8.Remove the two screws to release the module (see letter “A”).

9.Lift the module from the server system (see letter “B”).

A Figure 78. Removing the Power Distribution Module

B

A

AF000146

Figure 78. Removing the Power Distribution Module

10.Set the replacement power supply distribution module into the server system and screw the module into place.

11.Install the hot-swap power supply/supplies. For instructions, see “Replacing the Power Supply”.