Kodak 1200I manual Waste Bottle Missing, Mainboard Id Error, 0 = “MBID Error - Record Mismatch!”

Models: 1200I

1 74
Download 74 pages 13.31 Kb
Page 58
Image 58
WASTE BOTTLE MISSING!

KODAK 1200i WIDE-FORMAT PRINTING SYSTEM

WASTE BOTTLE MISSING!

1.Insert or reinstall waste bottle. The actuator arm located at the inside rear of the auto clean unit controls the sensor activation. If the error persists then contact technical support.

2.Bottle present sensor may be defective; contact technical support for assistance.

MAINBOARD ID ERROR!

This alarm provides the top-level MBID error status only. Additional information about the specific error is available if the operator presses the “More Info” button. The following is a list of all possible “More Info” specific error messages that follow “Mainboard ID Error”:

MBID Error – Code < # > (# ranges from 0 to 7)

Where:

0 = “MBID Error - Record Mismatch!”

2 = “MBID Error - Pri CRC Failed!”

3 = “MBID Error - Sec CRC Failed!”

4 = “MBID Error - No Response!”

5 = “MBID Error - Write Protected!”

6 = “MBID Error - Copy Failed!”

7 = “MBID Error - MAC Mismatch!”

Translation: The ID-chip or its connection is faulty.

There is one more unique MBID error that can occur. This error will be displayed only if there is an invalid OEM byte sent to the main-board chip at initialization time. The OEM field is read from the ID chip. 1 = Kodak 1200i, 4 = POS, 5 = Special, 6 = Xerox 8142/8160.

“MBID ERROR - INVALID OEM ID!”

In this instance, the manufacturer is required to change the OEM designation to an approved OEM value before attempting another MBID Initialization process. The Main PWA must be returned to the manufacturer as the software/hardware components cannot be released outside of manufacturing.

NOTE: For printing to occur (be authorized) the main board OEM number must also match the cartridge OEM value and the refill bottle OEM value. For example, the KODAK printer version (UTILITY MENU – SERVICE MENU – ABOUT) must have a main board value of 1 (i.e. MB: 90_01), the six cartridges (UTILITY MENU – SERVICE MENU – CART INFO) must all be a value of 1, and the six refill bottles must all be a value of 1. As well, the cartridges and bottles must also have matching ink type (i.e. QiD) If a mismatch occurs printing will not be allowed. Replace cartridge or ink bottle if a mismatch occurs.

Technical Training Guide

58

Page 58
Image 58
Kodak 1200I Waste Bottle Missing, Mainboard Id Error, 0 = “MBID Error - Record Mismatch!”, 4 = “MBID Error - No Response!”