Step 10: Activate ‘Prime All’ Test Pattern
-To print the Prime pattern select Utility Menu - Prime Menu - Prime All. Verify print head nozzle performance - ensure diagonal lines are smooth and clogged jets are not present.
-If necessary perform Manual Jet Bypass for clogged or misfiring jets. Select Utility Menu – Calibration Menu – Open Jet Menu – Edit List Menu. Scroll to particular jet number which has the clog/problem and toggle off. Select Ok to save selection.
NOTE: A few ‘streaks’ or lines may appear in the