Specifications
57
IntroductionOperationParametersAppendix
Specications
INPUT/OUTPUT connectors: SCSI connector, ANALOG IN 1/2 connectors, S/
P DIF IN/OUT connectors
Sampling frequency: 48 kHz
Recording time: when using a 540 Mbyte hard disk, approximately 94 minutes
of monaural recording, approximately 47 minutes of stereo recording (approxi-
mately 5 Mbytes per minute of monaural recording)
Tracks recorded simultaneously: 2
Tracks played back simultaneously: 4
Digital mixer specifications
Volume: 0—127 (100=unity)
High EQ: –15—+15 (0=unity)
Low EQ: –15— +15 (0=unity)
Send 1: 0—127 (send to Master Effect 1)
Send 2: 0—127 (send to Master Effect 2)
Pan: L000—C064—R127, OFF
Analog audio input gain structure
S/N ratio (A-weighted): better than 90 dB
Measured at OUTPUT 1 and 2 for a 1 kHz sine wave input, Rec Level=0.0,
AT1: Pan=L000, Volume=100, AT2: Pan=R127, Volume=100, AT3/4: MUTE
Action: Lower the Input Level and/or Rec Level settings so that the Over-
load and/or Over displays do not appear.
Cause 2: Even if the Input Level and Rec Level settings are appropriate, dis-
torted sound will be output from the monitor if the P1 tab 6 page
(Mix Audio Track 1–4) Volume setting is too high. (However the
sound that is recorded is not distorted.)
Action: Adjust the volume downward. A volume setting of 0 is -infinity, 100
is 0 dB, and 127 is +127 dB.
Cause 3: In situations other than the above, the output from the monitor will
be distorted if Pan is set to C064 during stereo recording.
Action: During stereo recording, set Pan to L000 and R127.
Problem: Sound is not output from the monitor even though the level meters
are up.
Cause 1: There is a problem with the settings of the TRINITY itself or with the
connections.
Action: Raise the TRINITY’s volume, or check the monitor connections.
Cause 2: An audio track is not selected in Track.
Action: Select an audio track.
Cause 3: Even if an audio track is selected, the tab 6 page (Mix A1–4) Volume
setting is 0, or Pan is OFF.
Action: Adjust the Volume and Pan settings.
Input Level setting Typical input level Max input level Typical gain
30 dBu 30 dBu 20 dBu +20 dB
10 dBu 10 dBu 0 dBu 0 dB
+4 dBu +4 dBu +14 dBu 14 dB