Installer Menu (Cont.)

Installer Menu Items 071 through 122

Item

Function

Value Range

Default Value

Brief Description of Function

 

 

 

 

 

071

BCK. CH-TIME

0 ~ 7

2

Chooses custom background color for the STB’s Channel-Time display.

 

 

 

 

If set to 1 and item 028 CH. OVERIDE is set to 0, a “CHANNEL NOT

073

CH NOT AVBLE

0 / 1

0

AVAILABLE” message is displayed if user attempts to direct tune a channel that

 

 

 

 

is not included in the channel lineup.

075

REVERT CH

0 / 1

0

If set to 1 and loss of MPI communication occurs, STB tunes to Start Channel.

 

 

 

 

 

078

UPN MSB

0 ~ 255

0

User programmable number, most significant byte.

079

UPN MSB-1

0 ~ 255

0

User programmable number, most significant byte - 1.

 

 

 

 

 

080

UPN MSB-2

0 ~ 255

0

User programmable number, most significant byte - 2.

 

 

 

 

 

081

UPN LSB

0 ~ 255

0

User programmable number, least significant byte.

082

CHKSM ERROR

0 / 1

1

Enforces rigid MPI checksum.

083

HANDSHK TIME

0 ~ 5

5

Relaxes MPI timing to be compatible with PC-based Windows-controlled systems.

084

PERMANENT BLK

0 / 1

0

Removes block hours setting for Parental Control and makes block permanent.

086

V. MUTE TIME 

0 ~ 50

0

Use to extend the normal video mute time during channel change.

088

EN NOISE MUTE

0 / 1

1

(Analog channels only) If set to 1, audio is muted if no signal is present.

090

KEY LOCK

0 / 1

1

If set to 1, all LG Hospitality and commercial non-LG display panel button

functions are locked. N/A for LG Public Displays or LG Commercial Monitors.

 

 

 

 

091

HDMI2 ENABLE

0 ~ 2

1

Set to 0 to disable HDMI 2. Set to 1 (DTV Mode) or 2 (PC Mode), as

applicable, to enable HDMI 2.

 

 

 

 

094

SAP MENU EN

0 / 1

1

Set to 1 to enable SAP feature in Function Menu.

096

DEF. ASP. RATIO

0 ~ 4

2

Sets default aspect ratio at power up. See detailed descriptions and item 106.

097

AUDIO OUTPUT

0 / 9

9

Set as required in accordance with external audio equipment connected to the

STB. (See detailed descriptions.)

 

 

 

 

098

PRO:CENTRIC

0 ~ 3

0

Set to 0 to disable Pro:Centric operation. Set to 1 for Flash Mode. Set to 2 for

GEM (Java Application) Mode. Set to 3 for HTML Mode.

 

 

 

 

100

VIDEO INTERFAC

3 ~ 5

3

Selects HDMI connection for display panel: 3 = HDMI1, 4 = HDMI2, 5 = HDMI3

101

IR FEEDBACK

0 / 2

0

Set to 2 to disable the STB’s Bluetooth feature.

102

ATSC BAND

0 ~ 4

4

Selects ATSC band.

103

ATSC TUNE MODE

0 / 1

1

Set to 1 (default) for Physical Channel scan. Set to 0 for Virtual Channel scan.

104

START MINOR CH

0 ~ 255

0

Selects Minor Start Channel. Set to 0 for NTSC.

105

VID OUT FORMAT

1, 4, 5

1

Sets format for video output: 1 = 720p, 4 = 1080p, 5 = 1366 x 768

 

 

 

 

 

106

ASP RATIO LOCK

0 / 1

0

To retain set aspect ratio on power cycle, set to 1. Set to 0 for default ratio on

power cycle.

 

 

 

 

108

PANEL COM

0 ~ 3

2

Sets display panel baud rate: 0 = 1200, 1 = 2400, 2 = 9600, 3 = 115200

110

PANEL DELAY

0 ~ 15

8

Sets the display panel communication delay time.

111

PANEL VOL PRE

0 ~ 100

100

Determines a preset fixed volume level to set in the display panel.

113

PANEL TYPE

0 ~ 4

4

Sets display panel communication command set. (See detailed descriptions.)

116

VIDEO MUTE EN

0 / 1

0

(Analog channels only) If set to 1, video mutes (blank screen) when no

signal is present.

 

 

 

 

117

FACT DEFAULT

0 / 1

0

Set to 1 to restore the factory default settings of all Installer Menu items.

 

 

 

 

 

 

 

0 ~ 135, 253,

 

Set to 0 to disable. Set from 1 to 135 to match the RF channel number used by

119

DATA CHANNEL

255

the Pro:Centric server as its data channel. Set to 255 to use Auto Search to find

255

 

 

 

the Pro:Centric RF channel. (See detailed descriptions.)

 

 

 

 

 

 

 

 

 

121

UPDATE TIME HR

0 ~ 23, 128

128

Sets the Wake For Update hour. The value “128” is displayed as “OFF.” Directly

entering 128 turns the Wake For Update feature OFF.

 

 

 

 

122

UPDATE TIME MN

0 ~ 59, 255

0

Sets the minute for Wake For Update. (See detailed descriptions.)

32

 

 

 