Installer Menu (Cont.)
008 - MIN VOLUME (Minimum Volume)
This function determines the minimum volume level allowable with the Volume (VOL) Up/Down control. In this way, for example, someone cannot set the volume too low to hear. The value range is from 0 to 63. The factory default is 0, which provides the full range of volume control, if item 009 MAX VOLUME is set to 63. It is recommended to set the same value on every STB.
Note: The minimum volume level cannot have a value setting higher than the maximum volume level (described below).
009 - MAX VOLUME (Maximum Volume)
This function determines the maximum volume level allowable with the Volume (VOL) Up/Down control. In this way, for example, someone cannot set the volume level high enough to disturb others. The value range is 0 to 63, with 63 as the default, which gives the user the full range of volume control, if item 008 MIN VOLUME is set to 0. It is recommended to set the same value on every STB.
Note: The maximum volume level cannot have a value setting lower than the minimum volume level (described above).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot be muted. If set to 0, sound can be muted.
011 - KEY DEFEAT
Applicable for LG Hospitality and commercial
Note: Users can always access the STB’s menus by pressing MENU on the remote.
Note: This feature does not apply to LG Public Displays or LG Commercial Monitors since the STB will always disable those displays’ panel buttons and the processing of IR.
015 - SLEEP TIMER
If set to 1, the Sleep Timer feature may be used. If set to 0, the Sleep Timer is not available.
016 - EN. TIMER (Enable On/Off Timers)
If set to 1, the Timer function is available to the end user and enabled continuously. Set to 0 to disable On/Off timers.
Note: The STB clock must be set in order for timers to be used.
017 - ALARM
Gives the installer the option of making the Alarm function available to the end user. If set to 1, the Alarm function is available to the end user. Set to 0 to disable the Alarm function.
Note: The STB clock must be set before the Alarm function will work.
020 - FEATURE LEVEL
Determines an additional IR code scheme to which the STB will respond, allowing for the use of unique IR codes based on “bed number” in a
Values | IR Mode | Bed # |
0 | Disabled | N/A |
|
|
|
Note: The
021 -
Set to 1 to activate
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours from 0 to 99 for the maximum
Note: This item is not available in the Installer Menu when item 021
023 - CAPTION LOCK
If set to 0, captions are OFF when the STB/display panel is turned ON. Set to 1 to use the caption setting configured before the STB/ display was turned OFF when the STB/display is turned ON.
028 - CH. OVERIDE (Channel Override)
Applicable for
029 - OLD OCV (On Command Video™)
Set to 1 to remap the PTC’s direct tune channels for Aux inputs from 13x to 9x. This allows
030 - ACK MASK
MPI Communication Parameter. When set to 1, enables ACK feature of MPI.
34 |